Professor Zhang Shanduan: Four Evaluation Indicators for Green Lighting
At the "2012 China Senior Lighting Designers Forum" held on December 20, Zhang Shanduan, Associate Professor of the Department of Light Sources and Lighting Engineering at Fudan University, presented several views on green lighting. He believes that there are generally four evaluation indicators for green lighting: energy saving, environmental protection, safety, and comfort. The most important is safety.
Energy-saving indicators include the luminous efficacy, lifespan, and lumen maintenance rate of luminaires. Environmental indicators refer to low emissions of harmful substances and the amount of electrical energy consumed during use. The carbon footprint refers to the carbon emissions generated during the processes of production, transportation, consumption, and disposal. "Europeans are bluffing that the carbon footprint can be calculated, considering whether to impose carbon taxes on lighting products," he said. In terms of safety, the first is electrical safety, followed by photobiological safety, such as UV damage and blue light damage. Comfort indicators include color temperature, color rendering index, DUV, SDCM, UGR, and so on.
● Indicator 1: Energy Saving (Luminous Efficacy, Lifespan, Lumen Maintenance Rate)
1. Light Efficacy: Unsaturated ceramic metal halide lamps may be mass-produced in 2015-2020 but at a high price
Zhang Shanduan shared in detail the four major evaluation indicators. In terms of energy saving, he predicted the light efficacy trend for 2015-2020. "Currently, foreign countries are keen on improving the light efficacy of tungsten halogen lamps, which is expected to reach 30-40 lm/W." He believes that if the cost of infrared coating can be reduced, tungsten halogen lamps can replace incandescent lamps. Fluorescent lamps using T8 straight tubes can reach a light efficacy of 120 lm/W, and CFLs have reached 85 lm/W. Foreign countries no longer improve the light efficacy of high-pressure sodium lamps, while in China, using sintered electrodes, 250W high-pressure sodium lamps can achieve a light efficacy of 160 lm/W. From 2015 to 2020, unsaturated ceramic metal halide lamps may be mass-produced, with a color rendering index of 98 and a spectrum close to the blackbody line, but the price is relatively high because the sealing material uses the precious metal iridium. He stated that by around 2020, LEDs currently with a single light-emitting area of 1mm2, a current of 350mA, and a power of 1W can achieve a current of 1.5A and a power of 4W or above, with warm white light efficacy reaching 150 lm/W and cool white light efficacy reaching 180 lm/W.
2. Lifespan: 10,000 hours of lifespan is more suitable for LED lighting
Regarding lifespan, Zhang Shanduan stated that fluorescent lamps have achieved a 90% survival rate at 16,000 hours, high-pressure sodium lamps 25,000-30,000 hours, and ceramic metal halide lamps 15,000-25,000 hours. According to LED manufacturers, the lifespan of LEDs today is 20,000-30,000 hours, or even 35,000 hours. He questioned: "Does it make sense to be this long? Especially for household or commercial lighting, a lifespan of more than 5 years has no meaning, and after 10 years the home will be renovated anyway." He also pointed out that Robin Devonshire, chairman of the International Commission on Illumination, made a prediction that if the lifespan of LEDs exceeds 25,000 hours and continues to increase, LED sales will decline by 2017, "because the lamps last too long and the number of lamps needing replacement decreases. This is not good for the sustainable development of the lighting industry. I personally believe that a lamp lifespan of 10,000 hours is more appropriate."
3. Lumen Maintenance: Will reach a higher level in the future
Zhang Shanduan believes that lumen maintenance is very important. "My lamp works well when first installed, but it decays quickly. Good fluorescent lamps have a lumen maintenance rate of 90% at 16,000 hours, sodium lamps can reach 90% at 20,000 hours, and ceramic metal halide lamps are at 62% at 20,000 hours. He said that the current national bidding documents require LEDs to have a lumen maintenance rate of 86% at 10,000 hours." Based on actual measurement results, Fudan University has also installed dozens of LED street lights, with a lumen maintenance rate of 93% at 5,000 hours. He predicts that in the future, the luminous efficacy and lumen maintenance rate of lamps can be made relatively high, and the overall trend is that the development of traditional light sources will be slower, while the LED process will be faster.
● Indicator 2: Environmental Protection (Low Harmful Substance Emissions, Carbon Footprint)
1. Misconceptions about fluorescent lamps
Misconception 1: Electromagnetic radiation exceeds standards
From the environmental perspective, Zhang Shanduan hopes that the harmful substances emitted during the manufacturing, transportation, use, and disposal of lamps should be as little as possible. "There are some misconceptions about fluorescent lamps. The first is the issue of electromagnetic radiation. Earlier this year, Shanghai Oriental TV Station hired a non-professional who used high-frequency equipment to test, and the electromagnetic radiation of the energy-saving lamps was measured to be very high. Later, the National Electric Light Source Quality Supervision and Inspection Center in Shanghai purchased many energy-saving lamps from the market for testing, and the results showed no problems. Why did the non-professional measure such a big problem with the electromagnetic radiation of energy-saving lamps? This is because their testing equipment and testing methods had problems. According to Yu Anqi, the director of the Shanghai Illumination Society, the electromagnetic radiation of energy-saving lamps and HID lamps is very small."
Misconception 2: Severe Mercury Pollution
The second issue is mercury pollution. He stated that if fluorescent lamps are filled with liquid mercury and it leaks from energy-saving lamps or straight-tube fluorescent lamps, the indoor mercury concentration will definitely exceed the standard. "A few years ago, dozens of kilograms of mercury leaked from the production line of a fluorescent lamp manufacturer, and some workers suffered mercury poisoning. The production line was then stopped for several months and entirely switched to solid mercury filling," he explained. Now all domestic energy-saving lamps have adopted solid mercury filling. If solid mercury is exposed to the air, the concentration of mercury released is completely within the national safety range. Currently, the mercury content in fluorescent lamps is already very low. High-performance domestic energy-saving lamps can be controlled to 0.8 milligrams, and the lamp life can still reach 8,000-10,000 hours. Therefore, in the future, mercury pollution should not become a reason for LEDs to attack fluorescent lamps.
2. Carbon Footprint: The Lighting Industry Lacks Sufficient Parameters for Calculation
"Carbon footprint is an issue that Europe is currently promoting. It refers to the carbon emissions caused by the processes of production, transportation, consumption and waste disposal — such as the energy used in manufacturing, and the energy required for processing and recycling. They want to measure it as carbon emissions," he stated. In the lighting industry, there is no such calculation yet. "I had my graduate students conduct research and found that many parameters cannot be obtained, so it cannot be calculated yet."
3. Carbon Reduction: Carbon Dioxide Is a Secondary Factor
Regarding the purpose of carbon reduction, Zhang Shanduan believes that the primary goal is energy conservation, "which in practice reduces our country's energy pressure, whether imported or domestically extracted." Carbon dioxide is now considered the primary factor causing global warming, but there is still significant debate based on scientific evidence. He is more inclined to think that CO2 is a secondary factor, and that the sun's periodic activity causing global warming is primary. He suggests that everyone recognize that Europe and America are alienating carbon emissions into carbon politics and Wall Street's carbon finance.
Page 2: Safety and Comfort Indicators
● Indicator 3: Safety (Electrical Safety, Photobiological Safety)
Regarding safety, electrical safety is the primary concern. There is also photobiological safety, including UV, blue light, near-infrared harm, as well as non-visual biological effects. "Based on our preliminary test results last year, we found that if no treatment is applied, the blue light dosage of transparent LEDs will definitely exceed the standard. Only frosted incandescent lamps and low color temperature LEDs with diffused light meet the blue light safety requirements. There are no very clear standards yet for non-visual biological effects," he said.
#p#Page Title#e# ● Indicator 4: Comfort (Color Temperature, Color Rendering Index, DUV, SDCM, UGR, Lifetime Maintenance of Color Parameters)
In terms of comfort indicators, the human body adapts to continuous spectra. Color temperature should take into account the application scenario and the needs of the human physiological rhythm. To achieve a color rendering index above 90 for LEDs, a red light chip needs to be added.
In addition, comfort indicators also include DUV, standard color deviation, glare, and the lifetime maintenance of color parameters. Color temperature and standard color deviation must remain stable throughout the lifetime.
Zhang Shanduan also raised the question of what other parameters are needed to judge lighting comfort. The first is R9>0, and the second is the flicker issue. He said: "Currently there is a new high-voltage LED solution that does not require a driver. After mains rectification, it is used directly to light LED lamps, which may cause a 100Hz flicker issue. There are also uniformity, diffusion, and even more physical concepts—polarization degree, coherence—which still need further research. This depends on the joint efforts of lighting experts and those specializing in light sources to see whether we can quantify the 'comfort' we feel, so that in the future these metrics can be used for assessment."
Finally, he raised several questions worth questioning—"Can LEDs dominate everything?" He personally believes it is not possible. The glare control of LED luminaires is worth researching, and indirect lighting is the direction. In addition, can average-quality LEDs produce good luminaires? For example, using LED packages with different parameters and, through sorting, combining them into luminaires with consistent color temperature, DUV, and SDCM—this is a low-cost solution.
China Light
Site oficial da Associação Chinesa da Indústria de Iluminação e plataforma multimédia do setor de iluminação. Além de fornecer informações autorizadas e oportunas sobre iluminação, procuramos ser parceiros do crescimento das empresas. Da promoção de marcas e expansão de canais à consultoria, formação de talentos e participação na elaboração de normas, oferecemos serviços profissionais abrangentes para ajudar as empresas a melhorar a qualidade e a eficiência e promover conjuntamente o desenvolvimento de alta qualidade da indústria da iluminação.
Contactos para colaboração
仇纯 (Sra.): 158 6155 3579
顾君 (Sr.): 137 7157 5253